PS-HDC 250/4R
|
16.75/17.85/18.92 kW heating capacity or 14.95/15.83/16.70 kW cooling capacity in 4 row heat exchanger, air flow 1880/2025/2170 m³/h, max. sound pressure level 53 dB(A), max. fan power 420 W, dimensions 1000x880xH420 mm, weight 88 kg, 2 year WARRANTY |
|
PS-HDC 250/4R
|
16.75/17.85/18.92 kW heating capacity or 14.95/15.83/16.70 kW cooling capacity in 4 row heat exchanger, air flow 1880/2025/2170 m³/h, max. sound pressure level 53 dB(A), max. fan power 420 W, dimensions 1000x880xH420 mm, weight 88 kg, 2 year WARRANTY |
PS-HDC 370/4R
|
31.73/34.01/35.86 kW heating capacity or 27.79/29.62/31.05 kW cooling capacity in 4 row heat exchanger, air flow 3720/4050/4325 m³/h, max. sound pressure level 52 dB(A), max. fan power 770 W, dimensions 1400x880xH420 mm, weight 96 kg, 2 year WARRANTY |
|
PS-HDC 370/4R
|
31.73/34.01/35.86 kW heating capacity or 27.79/29.62/31.05 kW cooling capacity in 4 row heat exchanger, air flow 3720/4050/4325 m³/h, max. sound pressure level 52 dB(A), max. fan power 770 W, dimensions 1400x880xH420 mm, weight 96 kg, 2 year WARRANTY |
PS-HDC 400/4R
|
35.44/37.69/39.47 kW heating capacity or 31.15/32.83/34.34 kW cooling capacity in 4 row heat exchanger, air flow 4120/4440/4700 m³/h, max. sound pressure level 54 dB(A), max. fan power 860 W, dimensions 1600x880xH420 mm, weight 106 kg, 2 year WARRANTY |
|
PS-HDC 400/4R
|
35.44/37.69/39.47 kW heating capacity or 31.15/32.83/34.34 kW cooling capacity in 4 row heat exchanger, air flow 4120/4440/4700 m³/h, max. sound pressure level 54 dB(A), max. fan power 860 W, dimensions 1600x880xH420 mm, weight 106 kg, 2 year WARRANTY |
PS-HDC 570/4R
|
43.15/45.83/48.41 kW heating capacity or 37.80/39.85/41.91 kW cooling capacity in 4 row heat exchanger, air flow 5080/5470/5860 m³/h, max. sound pressure level 55 dB(A), max. fan power 970 W, dimensions 1800x880xH420 mm, weight 135 kg, 2 year WARRANTY |
|
PS-HDC 570/4R
|
43.15/45.83/48.41 kW heating capacity or 37.80/39.85/41.91 kW cooling capacity in 4 row heat exchanger, air flow 5080/5470/5860 m³/h, max. sound pressure level 55 dB(A), max. fan power 970 W, dimensions 1800x880xH420 mm, weight 135 kg, 2 year WARRANTY |
PS-HDC 690/4R
|
49.45/52.44/55.62 kW heating capacity or 43.02/45.42/47.82 kW cooling capacity in 4 row heat exchanger, air flow 5855/6300/6780 m³/h, max. sound pressure level 53 dB(A), max. fan power 1220 W, dimensions 2000x880xH420 mm, weight 176 kg, 2 year WARRANTY |
|
PS-HDC 690/4R
|
49.45/52.44/55.62 kW heating capacity or 43.02/45.42/47.82 kW cooling capacity in 4 row heat exchanger, air flow 5855/6300/6780 m³/h, max. sound pressure level 53 dB(A), max. fan power 1220 W, dimensions 2000x880xH420 mm, weight 176 kg, 2 year WARRANTY |
|
PS-HDCE 250/4R
|
7.91/15.36/21.03 kW heating capacity or 7.53/13.89/18.43 kW cooling capacity in 4 row heat exchanger, air flow 820/1700/2465 m³/h, max. sound pressure level 51 dB(A), max. fan power 300 W, dimensions 1000x880xH420 mm, weight 88 kg, 2 year WARRANTY |
|
PS-HDCE 250/4R
|
7.91/15.36/21.03 kW heating capacity or 7.53/13.89/18.43 kW cooling capacity in 4 row heat exchanger, air flow 820/1700/2465 m³/h, max. sound pressure level 51 dB(A), max. fan power 300 W, dimensions 1000x880xH420 mm, weight 88 kg, 2 year WARRANTY |
PS-HDCE 370/4R
|
11.78/26.13/35.86 kW heating capacity or 11.23/23.29/31.05 kW cooling capacity in 4 row heat exchanger, air flow 1220/2950/4325 m³/h, max. sound pressure level 50 dB(A), max. fan power 720 W, dimensions 1400x880xH420 mm, weight 96 kg, 2 year WARRANTY |
|
PS-HDCE 370/4R
|
11.78/26.13/35.86 kW heating capacity or 11.23/23.29/31.05 kW cooling capacity in 4 row heat exchanger, air flow 1220/2950/4325 m³/h, max. sound pressure level 50 dB(A), max. fan power 720 W, dimensions 1400x880xH420 mm, weight 96 kg, 2 year WARRANTY |
PS-HDCE 400/4R
|
13.94/30.17/39.47 kW heating capacity or 13.25/26.89/34.34 kW cooling capacity in 4 row heat exchanger, air flow 1445/3400/4700 m³/h, max. sound pressure level 52 dB(A), max. fan power 670 W, dimensions 1600x880xH420 mm, weight 106 kg, 2 year WARRANTY |
|
PS-HDCE 400/4R
|
13.94/30.17/39.47 kW heating capacity or 13.25/26.89/34.34 kW cooling capacity in 4 row heat exchanger, air flow 1445/3400/4700 m³/h, max. sound pressure level 52 dB(A), max. fan power 670 W, dimensions 1600x880xH420 mm, weight 106 kg, 2 year WARRANTY |
PS-HDCE 570/4R
|
17.51/34.99/48.41 kW heating capacity or 16.49/31.21/41.91 kW cooling capacity in 4 row heat exchanger, air flow 1825/3950/5860 m³/h, max. sound pressure level 53 dB(A), max. fan power 1120 W, dimensions 1800x880xH420 mm, weight 135 kg, 2 year WARRANTY |
|
PS-HDCE 570/4R
|
17.51/34.99/48.41 kW heating capacity or 16.49/31.21/41.91 kW cooling capacity in 4 row heat exchanger, air flow 1825/3950/5860 m³/h, max. sound pressure level 53 dB(A), max. fan power 1120 W, dimensions 1800x880xH420 mm, weight 135 kg, 2 year WARRANTY |
PS-HDCE 690/4R
|
21.52/40.94/55.62 kW heating capacity or 20.0/36.08/47.82 kW cooling capacity in 4 row heat exchanger, air flow 2260/4665/6780 m³/h, max. sound pressure level 51 dB(A), max. fan power 1060 W, dimensions 2000x880xH420 mm, weight 176 kg, 2 year WARRANTY |
|
PS-HDCE 690/4R
|
21.52/40.94/55.62 kW heating capacity or 20.0/36.08/47.82 kW cooling capacity in 4 row heat exchanger, air flow 2260/4665/6780 m³/h, max. sound pressure level 51 dB(A), max. fan power 1060 W, dimensions 2000x880xH420 mm, weight 176 kg, 2 year WARRANTY |