Vai jūs interesē šis produkts? Sazinieties ar mums:

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Latvijas tirdzniecības pārstāvja vietnieks Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
GAHP-AR - reversible, on heating operation mode takes heat from Air and gives it to Water for heating, on cooling operation mode takes heat from Water for cooling and gives it to Air
GAHP-AR STANDARD Maximum outlet water temperature for heating 60°C, heating capacity 37.8 kW (A7/W35), G.U.E. gas utilization efficiency for heating 150% (A7/W35), A+ energy class ErP on 55°C operation, minimum outlet water temperature for cooling 3°C, cooling capacity 16.9 kW (A35/W7), G.U.E. gas utilization efficiency for cooling 67% (A35/W7), gas (G20) consumption 2.67 m³/h, electrical power consumption 0.84 kW, sound pressure level (at 5 m distance) 57.6 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 380 kg, outside working temperature in heating mode -20°C/+35°C, outside working temperature in cooling mode 0°C/+45°C
GAHP-AR STANDARD
Maximum outlet water temperature for heating 60°C, heating capacity 37.8 kW (A7/W35), G.U.E. gas utilization efficiency for heating 150% (A7/W35), A+ energy class ErP on 55°C operation, minimum outlet water temperature for cooling 3°C, cooling capacity 16.9 kW (A35/W7), G.U.E. gas utilization efficiency for cooling 67% (A35/W7), gas (G20) consumption 2.67 m³/h, electrical power consumption 0.84 kW, sound pressure level (at 5 m distance) 57.6 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 380 kg, outside working temperature in heating mode -20°C/+35°C, outside working temperature in cooling mode 0°C/+45°C
GAHP-AR LOW-NOISE Maximum outlet water temperature for heating 60°C, heating capacity 37.8 kW (A7/W35), G.U.E. gas utilization efficiency for heating 150% (A7/W35), A+ energy class ErP on 55°C operation, minimum outlet water temperature for cooling 3°C, cooling capacity 16.9 kW (A35/W7), G.U.E. gas utilization efficiency for cooling 67% (A35/W7), gas (G20) consumption 2.67 m³/h, electrical power consumption 0.87 kW, sound pressure level (at 5 m distance) 53.0 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 390 kg, outside working temperature in heating mode -20°C/+35°C, outside working temperature in cooling mode 0°C/+45°C
GAHP-AR LOW-NOISE
Maximum outlet water temperature for heating 60°C, heating capacity 37.8 kW (A7/W35), G.U.E. gas utilization efficiency for heating 150% (A7/W35), A+ energy class ErP on 55°C operation, minimum outlet water temperature for cooling 3°C, cooling capacity 16.9 kW (A35/W7), G.U.E. gas utilization efficiency for cooling 67% (A35/W7), gas (G20) consumption 2.67 m³/h, electrical power consumption 0.87 kW, sound pressure level (at 5 m distance) 53.0 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 390 kg, outside working temperature in heating mode -20°C/+35°C, outside working temperature in cooling mode 0°C/+45°C
Izvēlieties produkta modeli:
GAHP-AR reversible gas absorption heat pump Air/Water
Manuals 9.4 MB
Atbilstības deklarācijas 2.8 MB
Katalogi 3.5 MB
Heating and cooling capacity tables 29 KB
BIM objects 11.1 MB
Comfort Control Interface installation and use manual 798 KB
Multiple same model preassembled groups installation, user and maintenance manual 13.7 MB
Multiple preassembled groups (Link) installation, user and maintenance manual 15 MB
DDC control panel
Manuals 12.4 MB
Bukleti 795 KB
MODBUS protocol for connection to BMS 690 KB
RB100 (Robur Box 100) control interface
Manuals 3.1 MB
RB200 (Robur Box 200) control interface
Manuals 3.1 MB
Izvēlieties produkta modeli: