Gāzes sildītājs, for external installation on wall or roof, fully insulated casing, condensing version, with axial fan for free blowing inside room, pre-mix burner, 18-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
Vai jūs interesē šis produkts? Sazinieties ar mums: Saņemt piedāvājumu
Modelis: EOLO BC 55 AE MIX
Mixing chambers for EOLO NBC/BC units, can be used with units equipped with axial AE fans if no filters are used or only fresh outdoor air is filtered or only recirculated room air is filtered, if fresh outdoor air is filtered together with recirculated room air - units with centrifugal AC fans must be used
04CNCO8102 Mixing chamber for external EOLO NBC/BC 55 heaters, insulated, outdoor air is drawn from behind, recirculated air is drawn from below (type C) or from above (type D)
04CNCO8102
Mixing chamber for external EOLO NBC/BC 55 heaters, insulated, outdoor air is drawn from behind, recirculated air is drawn from below (type C) or from above (type D)
Fan housings for external EOLO NBC/BC MIX units
04CNCO92?? Fan housing for external EOLO NBC/BC AE MIX units with axial fan, used if heater is recirculating 100% of room air, insulated, recirculated air is drawn from below (type C) or from above (type D)
04CNCO92??
Fan housing for external EOLO NBC/BC AE MIX units with axial fan, used if heater is recirculating 100% of room air, insulated, recirculated air is drawn from below (type C) or from above (type D)
Sprauslas āra gaisa iesūkšanai
94AKKO2004 Outdoor air intake with antirain fins for external EOLO NBC/BC 55 heaters with air mixing chamber where outdoor air is drawn from behind (type C or D)
94AKKO2004
Outdoor air intake with antirain fins for external EOLO NBC/BC 55 heaters with air mixing chamber where outdoor air is drawn from behind (type C or D)
Internal air supply grille
04CNBC???? Internal air supply grille for external EOLO NBC/BC heaters, dimensions mm, horizontal fins
04CNBC????
Internal air supply grille for external EOLO NBC/BC heaters, dimensions mm, horizontal fins
Filters frames
94PAKF0603 Filter frame for mixing chamber of EOLO NBC/BC 55 heater, required if filter for recirculated indoor air is added
94PAKF0603
Filter frame for mixing chamber of EOLO NBC/BC 55 heater, required if filter for recirculated indoor air is added
Gaisa filtri
04CNFI2537 Air filter for mixing chamber of EOLO NBC/BC 55 heater, suitable for filtering both recirculated and outdoor air
04CNFI2537
Air filter for mixing chamber of EOLO NBC/BC 55 heater, suitable for filtering both recirculated and outdoor air
Vadības pultis
11ELST9524 Control panel SCP674V122T2 for 1 EOLO heater, delivered with IP54 protection class PVC box
11ELST9524
Control panel SCP674V122T2 for 1 EOLO heater, delivered with IP54 protection class PVC box
Additional accessories for gas fired heaters
04CEGL3001 Temperatūras sensors, iekšējs – IP20 EOLO
04CEGL3001
Temperatūras sensors, iekšējs – IP20 EOLO
04CEGL3003 Temperatūras sensors, iekšējs – IP56 EOLO
04CEGL3003
Temperatūras sensors, iekšējs – IP56 EOLO
11ELSI0200 Piedziņas ierīce, modulējama 0-10 V
11ELSI0200
Piedziņas ierīce, modulējama 0-10 V
11ELPO0201 Pozicionieris 0-10 V, izmantojams kopā ar 0-10 V modulējamām piedziņas ierīcēm; ļauj ērti iestatīt vārstu stāvokli
11ELPO0201
Pozicionieris 0-10 V, izmantojams kopā ar 0-10 V modulējamām piedziņas ierīcēm; ļauj ērti iestatīt vārstu stāvokli
04CNAC0695 Protection against air filter clogging, when the pressure switch is activated, the heater is switched off and the corresponding message is displayed on the control panel
04CNAC0695
Protection against air filter clogging, when the pressure switch is activated, the heater is switched off and the corresponding message is displayed on the control panel
Mounting brackets
04CNST????? Wall mounting bracket for EOLO NBC/BC heaters
04CNST?????
Wall mounting bracket for EOLO NBC/BC heaters
04CNST2583 Wall mounting bracket for EOLO NBC/BC 55 heater with air mixing chamber where outdoor air is drawn from behind (type C or D)
04CNST2583
Wall mounting bracket for EOLO NBC/BC 55 heater with air mixing chamber where outdoor air is drawn from behind (type C or D)
Service
ORF PDDB Gas fired air heater comissioning (electrical power connection, gas connection and fumes extraction checking of the installed device; checking with a detector for gas leakage from external gas connection valve to the device burner; measuring the actual gas pressure before and after the regulator when the device is operating; adjusting the burner power according to the manufacturer's instructions; adjusting the device for efficient operation using a flue gas analyzer; checking the operation of safety automatic devices; checking connection of the room thermostat)
ORF PDDB
Gas fired air heater comissioning (electrical power connection, gas connection and fumes extraction checking of the installed device; checking with a detector for gas leakage from external gas connection valve to the device burner; measuring the actual gas pressure before and after the regulator when the device is operating; adjusting the burner power according to the manufacturer's instructions; adjusting the device for efficient operation using a flue gas analyzer; checking the operation of safety automatic devices; checking connection of the room thermostat)