Gāzes sildītājs, for external installation on wall or roof, fully insulated casing, condensing version, with axial fan for free blowing inside room, pre-mix burner, 18-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
Vai jūs interesē šis produkts? Sazinieties ar mums: Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
EOLO NBC AE MIX - for external installation on wall or roof, fully insulated casing, non-condensing version, with axial fan for free blowing inside room, pre-mix burner
EOLO NBC 25 AE MIX 15-22 kW modulating thermal power capacity, air flow 2900 m³/h, air throw 13 m, fan power 0.26 kW, max. gas (G20) consumption 2.33 m³/h, weight 62 kg, 2 year WARRANTY
EOLO NBC 25 AE MIX
15-22 kW modulating thermal power capacity, air flow 2900 m³/h, air throw 13 m, fan power 0.26 kW, max. gas (G20) consumption 2.33 m³/h, weight 62 kg, 2 year WARRANTY
EOLO NBC 35 AE MIX 20-32 kW modulating thermal power capacity, air flow 3600 m³/h, air throw 17 m, fan power 0.35 kW, max. gas (G20) consumption 3.39 m³/h, weight 74 kg, 2 year WARRANTY
EOLO NBC 35 AE MIX
20-32 kW modulating thermal power capacity, air flow 3600 m³/h, air throw 17 m, fan power 0.35 kW, max. gas (G20) consumption 3.39 m³/h, weight 74 kg, 2 year WARRANTY
EOLO NBC 45 AE MIX 28-43 kW modulating thermal power capacity, air flow 4500 m³/h, air throw 19 m, fan power 0.56 kW, max. gas (G20) consumption 4.55 m³/h, weight 89 kg, 2 year WARRANTY
EOLO NBC 45 AE MIX
28-43 kW modulating thermal power capacity, air flow 4500 m³/h, air throw 19 m, fan power 0.56 kW, max. gas (G20) consumption 4.55 m³/h, weight 89 kg, 2 year WARRANTY
EOLO NBC 55 AE MIX 34-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
EOLO NBC 55 AE MIX
34-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
EOLO NBC 65 AE MIX 42-63 kW modulating thermal power capacity, air flow 7000 m³/h, air throw 25 m, fan power 0.69 kW, max. gas (G20) consumption 6.67 m³/h, weight 128 kg, 2 year WARRANTY
EOLO NBC 65 AE MIX
42-63 kW modulating thermal power capacity, air flow 7000 m³/h, air throw 25 m, fan power 0.69 kW, max. gas (G20) consumption 6.67 m³/h, weight 128 kg, 2 year WARRANTY
EOLO NBC 85 AE MIX 56-86 kW modulating thermal power capacity, air flow 9000 m³/h, air throw 27 m, fan power 1.12 kW, max. gas (G20) consumption 9.1 m³/h, weight 148 kg, 2 year WARRANTY
EOLO NBC 85 AE MIX
56-86 kW modulating thermal power capacity, air flow 9000 m³/h, air throw 27 m, fan power 1.12 kW, max. gas (G20) consumption 9.1 m³/h, weight 148 kg, 2 year WARRANTY
EOLO NBC 100 AE MIX 71-105 kW modulating thermal power capacity, air flow 11000 m³/h, air throw 30 m, fan power 1.48 kW, max. gas (G20) consumption 11.11 m³/h, weight 186 kg, 2 year WARRANTY
EOLO NBC 100 AE MIX
71-105 kW modulating thermal power capacity, air flow 11000 m³/h, air throw 30 m, fan power 1.48 kW, max. gas (G20) consumption 11.11 m³/h, weight 186 kg, 2 year WARRANTY
EOLO BC AE MIX - for external installation on wall or roof, fully insulated casing, condensing version, with axial fan for free blowing inside room, pre-mix burner
EOLO BC 25 AE MIX 8-22 kW modulating thermal power capacity, air flow 2900 m³/h, air throw 13 m, fan power 0.26 kW, max. gas (G20) consumption 2.33 m³/h, weight 62 kg, 2 year WARRANTY
EOLO BC 25 AE MIX
8-22 kW modulating thermal power capacity, air flow 2900 m³/h, air throw 13 m, fan power 0.26 kW, max. gas (G20) consumption 2.33 m³/h, weight 62 kg, 2 year WARRANTY
EOLO BC 35 AE MIX 11-32 kW modulating thermal power capacity, air flow 3600 m³/h, air throw 17 m, fan power 0.35 kW, max. gas (G20) consumption 3.39 m³/h, weight 74 kg, 2 year WARRANTY
EOLO BC 35 AE MIX
11-32 kW modulating thermal power capacity, air flow 3600 m³/h, air throw 17 m, fan power 0.35 kW, max. gas (G20) consumption 3.39 m³/h, weight 74 kg, 2 year WARRANTY
EOLO BC 45 AE MIX 15-43 kW modulating thermal power capacity, air flow 4500 m³/h, air throw 19 m, fan power 0.56 kW, max. gas (G20) consumption 4.55 m³/h, weight 89 kg, 2 year WARRANTY
EOLO BC 45 AE MIX
15-43 kW modulating thermal power capacity, air flow 4500 m³/h, air throw 19 m, fan power 0.56 kW, max. gas (G20) consumption 4.55 m³/h, weight 89 kg, 2 year WARRANTY
EOLO BC 55 AE MIX 18-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
EOLO BC 55 AE MIX
18-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
EOLO BC 65 AE MIX 22-63 kW modulating thermal power capacity, air flow 7000 m³/h, air throw 25 m, fan power 0.69 kW, max. gas (G20) consumption 6.67 m³/h, weight 128 kg, 2 year WARRANTY
EOLO BC 65 AE MIX
22-63 kW modulating thermal power capacity, air flow 7000 m³/h, air throw 25 m, fan power 0.69 kW, max. gas (G20) consumption 6.67 m³/h, weight 128 kg, 2 year WARRANTY
EOLO BC 85 AE MIX 28-86 kW modulating thermal power capacity, air flow 9000 m³/h, air throw 27 m, fan power 1.12 kW, max. gas (G20) consumption 9.1 m³/h, weight 148 kg, 2 year WARRANTY
EOLO BC 85 AE MIX
28-86 kW modulating thermal power capacity, air flow 9000 m³/h, air throw 27 m, fan power 1.12 kW, max. gas (G20) consumption 9.1 m³/h, weight 148 kg, 2 year WARRANTY
EOLO BC 100 AE MIX 32-103 kW modulating thermal power capacity, air flow 11000 m³/h, air throw 30 m, fan power 1.48 kW, max. gas (G20) consumption 11.11 m³/h, weight 186 kg, 2 year WARRANTY
EOLO BC 100 AE MIX
32-103 kW modulating thermal power capacity, air flow 11000 m³/h, air throw 30 m, fan power 1.48 kW, max. gas (G20) consumption 11.11 m³/h, weight 186 kg, 2 year WARRANTY
EOLO BC MIX external condensing gas fired heaters
Manuals 3.2 MB
Atbilstības deklarācijas 5.4 MB
Bukleti 3.5 MB
Control panel user instructions 413 KB
Control panel manual 796 KB
AutoCAD drawings 10.5 MB
EOLO NBC MIX external non-condensing gas fired heaters
Manuals 6.6 MB
Atbilstības deklarācijas 5.4 MB
Bukleti 3.5 MB
Control panel user instructions 413 KB
Control panel manual 796 KB
AutoCAD drawings 10.5 MB
SCM850 control panel
Manuals 1000 KB
MODBUS protocol for connection to BMS 241 KB
Modelis: EOLO BC 55 AE MIX
Mixing chambers for EOLO NBC/BC units, can be used with units equipped with axial AE fans if no filters are used or only fresh outdoor air is filtered or only recirculated room air is filtered, if fresh outdoor air is filtered together with recirculated room air - units with centrifugal AC fans must be used
04CNCO8102 Mixing chamber for external EOLO NBC/BC 55 heaters, insulated, outdoor air is drawn from behind, recirculated air is drawn from below (type C) or from above (type D)
04CNCO8102
Mixing chamber for external EOLO NBC/BC 55 heaters, insulated, outdoor air is drawn from behind, recirculated air is drawn from below (type C) or from above (type D)
Fan housings for external EOLO NBC/BC MIX units
04CNCO92?? Fan housing for external EOLO NBC/BC AE MIX units with axial fan, used if heater is recirculating 100% of room air, insulated, recirculated air is drawn from below (type C) or from above (type D)
04CNCO92??
Fan housing for external EOLO NBC/BC AE MIX units with axial fan, used if heater is recirculating 100% of room air, insulated, recirculated air is drawn from below (type C) or from above (type D)
Sprauslas āra gaisa iesūkšanai
94AKKO2004 Outdoor air intake with antirain fins for external EOLO NBC/BC 55 heaters with air mixing chamber where outdoor air is drawn from behind (type C or D)
94AKKO2004
Outdoor air intake with antirain fins for external EOLO NBC/BC 55 heaters with air mixing chamber where outdoor air is drawn from behind (type C or D)
Internal air supply grille
04CNBC???? Internal air supply grille for external EOLO NBC/BC heaters, dimensions mm, horizontal fins
04CNBC????
Internal air supply grille for external EOLO NBC/BC heaters, dimensions mm, horizontal fins
Filters frames
94PAKF0603 Filter frame for mixing chamber of EOLO NBC/BC 55 heater, required if filter for recirculated indoor air is added
94PAKF0603
Filter frame for mixing chamber of EOLO NBC/BC 55 heater, required if filter for recirculated indoor air is added
Gaisa filtri
04CNFI2537 Air filter for mixing chamber of EOLO NBC/BC 55 heater, suitable for filtering both recirculated and outdoor air
04CNFI2537
Air filter for mixing chamber of EOLO NBC/BC 55 heater, suitable for filtering both recirculated and outdoor air
Vadības pultis
11ELST9524 Control panel SCP674V122T2 for 1 EOLO heater, delivered with IP54 protection class PVC box
11ELST9524
Control panel SCP674V122T2 for 1 EOLO heater, delivered with IP54 protection class PVC box
Additional accessories for gas fired heaters
04CEGL3001 Temperatūras sensors, iekšējs – IP20 EOLO
04CEGL3001
Temperatūras sensors, iekšējs – IP20 EOLO
04CEGL3003 Temperatūras sensors, iekšējs – IP56 EOLO
04CEGL3003
Temperatūras sensors, iekšējs – IP56 EOLO
11ELSI0200 Piedziņas ierīce, modulējama 0-10 V
11ELSI0200
Piedziņas ierīce, modulējama 0-10 V
11ELPO0201 Pozicionieris 0-10 V, izmantojams kopā ar 0-10 V modulējamām piedziņas ierīcēm; ļauj ērti iestatīt vārstu stāvokli
11ELPO0201
Pozicionieris 0-10 V, izmantojams kopā ar 0-10 V modulējamām piedziņas ierīcēm; ļauj ērti iestatīt vārstu stāvokli
04CNAC0695 Protection against air filter clogging, when the pressure switch is activated, the heater is switched off and the corresponding message is displayed on the control panel
04CNAC0695
Protection against air filter clogging, when the pressure switch is activated, the heater is switched off and the corresponding message is displayed on the control panel
Mounting brackets
04CNST????? Wall mounting bracket for EOLO NBC/BC heaters
04CNST?????
Wall mounting bracket for EOLO NBC/BC heaters
04CNST2583 Wall mounting bracket for EOLO NBC/BC 55 heater with air mixing chamber where outdoor air is drawn from behind (type C or D)
04CNST2583
Wall mounting bracket for EOLO NBC/BC 55 heater with air mixing chamber where outdoor air is drawn from behind (type C or D)
Service
ORF PDDB Gas fired air heater comissioning (electrical power connection, gas connection and fumes extraction checking of the installed device; checking with a detector for gas leakage from external gas connection valve to the device burner; measuring the actual gas pressure before and after the regulator when the device is operating; adjusting the burner power according to the manufacturer's instructions; adjusting the device for efficient operation using a flue gas analyzer; checking the operation of safety automatic devices; checking connection of the room thermostat)
ORF PDDB
Gas fired air heater comissioning (electrical power connection, gas connection and fumes extraction checking of the installed device; checking with a detector for gas leakage from external gas connection valve to the device burner; measuring the actual gas pressure before and after the regulator when the device is operating; adjusting the burner power according to the manufacturer's instructions; adjusting the device for efficient operation using a flue gas analyzer; checking the operation of safety automatic devices; checking connection of the room thermostat)