Fan coil, for horizontal ceiling mounting, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection, 5.48/7.01/8.52 kW heating capacity in 1 row heat exchanger and 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x485xH220 mm, weight 39.5 kg, 2 year WARRANTY
Vai jūs interesē šis produkts? Sazinieties ar mums:

Roberts Priekulis

LV, RU, EN
+371 286 22395

Tirdzniecības pārstāvis Latvijā Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
PS-FLH 2T - for horizontal ceiling mounting, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FLH 2T 030 2.32/2.47/3.14 kW heating capacity or 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x485xH220 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLH 2T 030
2.32/2.47/3.14 kW heating capacity or 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x485xH220 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLH 2T 050 2.76/3.54/4.43 kW heating capacity or 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x485xH220 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLH 2T 050
2.76/3.54/4.43 kW heating capacity or 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x485xH220 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLH 2T 070 4.35/4.71/6.08 kW heating capacity or 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x485xH220 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLH 2T 070
4.35/4.71/6.08 kW heating capacity or 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x485xH220 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLH 2T 100 4.82/6.66/8.58 kW heating capacity or 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x485xH220 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLH 2T 100
4.82/6.66/8.58 kW heating capacity or 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x485xH220 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLH 4T - for horizontal ceiling mounting, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FLH 4T 034 2.43/2.54/3.07 kW heating capacity in 1 row heat exchanger and 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x485xH220 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLH 4T 034
2.43/2.54/3.07 kW heating capacity in 1 row heat exchanger and 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x485xH220 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLH 4T 054 3.06/3.75/4.46 kW heating capacity in 1 row heat exchanger and 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x485xH220 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLH 4T 054
3.06/3.75/4.46 kW heating capacity in 1 row heat exchanger and 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x485xH220 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLH 4T 074 4.64/4.95/6.00 kW heating capacity in 1 row heat exchanger and 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x485xH220 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLH 4T 074
4.64/4.95/6.00 kW heating capacity in 1 row heat exchanger and 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x485xH220 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLH 4T 104 5.48/7.01/8.52 kW heating capacity in 1 row heat exchanger and 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x485xH220 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLH 4T 104
5.48/7.01/8.52 kW heating capacity in 1 row heat exchanger and 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x485xH220 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLEH 2T - for horizontal ceiling mounting, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FLEH 2T 030 1.36/2.44/3.26 kW heating capacity or 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x485xH220 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLEH 2T 030
1.36/2.44/3.26 kW heating capacity or 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x485xH220 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLEH 2T 050 1.65/3.08/4.03 kW heating capacity or 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x485xH220 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLEH 2T 050
1.65/3.08/4.03 kW heating capacity or 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x485xH220 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLEH 2T 070 1.94/4.33/5.64 kW heating capacity or 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x485xH220 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLEH 2T 070
1.94/4.33/5.64 kW heating capacity or 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x485xH220 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLEH 2T 100 2.22/5.02/6.68 kW heating capacity or 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x485xH220 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLEH 2T 100
2.22/5.02/6.68 kW heating capacity or 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x485xH220 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLEH 4T - for horizontal ceiling mounting, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FLEH 4T 034 1.24/2.03/2.50 kW heating capacity in 1 row heat exchanger and 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x485xH220 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLEH 4T 034
1.24/2.03/2.50 kW heating capacity in 1 row heat exchanger and 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x485xH220 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLEH 4T 054 1.60/2.61/3.24 kW heating capacity in 1 row heat exchanger and 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x485xH220 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLEH 4T 054
1.60/2.61/3.24 kW heating capacity in 1 row heat exchanger and 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x485xH220 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLEH 4T 074 1.95/3.67/4.54 kW heating capacity in 1 row heat exchanger and 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x485xH220 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLEH 4T 074
1.95/3.67/4.54 kW heating capacity in 1 row heat exchanger and 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x485xH220 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLEH 4T 104 2.23/4.22/5.32 kW heating capacity in 1 row heat exchanger and 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x485xH220 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLEH 4T 104
2.23/4.22/5.32 kW heating capacity in 1 row heat exchanger and 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x485xH220 mm, weight 39.5 kg, 2 year WARRANTY
PS-FL / PS-FLE / PS-FLF / PS-FLEF / PS-FLH / PS-FLEH standard fan coil units
Manuals 356 KB
Bukleti 1.2 MB
Katalogi 527 KB
Fan coils controllers
Bukleti 8.1 MB
Modelis: PS-FLH 4T 104
Control panels for fan coils
TER.ANA Suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.ANA
Suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.ANA.S Suitable for 2-pipe and 4-pipe units with AC fans, automatic 3 steps fan speed selection, integrated thermostat, possibility to remotely turn device on/off, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units without valves
TER.ANA.S
Suitable for 2-pipe and 4-pipe units with AC fans, automatic 3 steps fan speed selection, integrated thermostat, possibility to remotely turn device on/off, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units without valves
TER.DIG Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.DIG
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.DIG.S Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to control additional electric heater, on/off valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.DIG.S
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to control additional electric heater, on/off valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BUS Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BUS
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BAC Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BAC
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
Accessories for fan coils controls
KIT.WI-FI Electronic board for remote control of PS-FS, PS-FL/FLF/FLH, PS-UWL/UWLF/UWLV, PS-DC/HDC fan coil units with AC type fan via Wi-Fi connection and app for smart Android / IOS devices, delivered with air temperature probe
KIT.WI-FI
Electronic board for remote control of PS-FS, PS-FL/FLF/FLH, PS-UWL/UWLF/UWLV, PS-DC/HDC fan coil units with AC type fan via Wi-Fi connection and app for smart Android / IOS devices, delivered with air temperature probe
IDP Power interface distributor that allows to use single TER.ANA / TER.ANA.M / TER.ANA.S / TER.ANA.S.M / TER.DIG / TER.DIG.M / TER.DIG.D / TER.DIG.D.M / TER.DIG.S / TER.TOUCH / TER.TOUCH.M control panel for up to 4 fan coil units with AC type fans
IDP
Power interface distributor that allows to use single TER.ANA / TER.ANA.M / TER.ANA.S / TER.ANA.S.M / TER.DIG / TER.DIG.M / TER.DIG.D / TER.DIG.D.M / TER.DIG.S / TER.TOUCH / TER.TOUCH.M control panel for up to 4 fan coil units with AC type fans
Water valves
ATT.230 On/Off actuator for water valve, powered by 230 V
ATT.230
On/Off actuator for water valve, powered by 230 V
ATT.MOD Modulating by 0-10 V signal actuator for water valve
ATT.MOD
Modulating by 0-10 V signal actuator for water valve
VAL.2V.12.FL 2-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.2V.12.FL
2-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.3V.12.FL 3-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.3V.12.FL
3-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.12.DIN.FL Balancing water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.12.DIN.FL
Balancing water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
Condensate drain pumps
POM.CON.20 Condensate drain pump for PS-WLE, PS-FL/FLF/FLH/FLE/FLEF/FLEH, PS-UWLED, PS-DC/DCE/HDC/HDCE fan coil units, flow rate 20 l/h
POM.CON.20
Condensate drain pump for PS-WLE, PS-FL/FLF/FLH/FLE/FLEF/FLEH, PS-UWLED, PS-DC/DCE/HDC/HDCE fan coil units, flow rate 20 l/h
Painting in non-standard colors
FL070.RAL Painting of casing in non-standard RAL color for 070 - 104 size PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units
FL070.RAL
Painting of casing in non-standard RAL color for 070 - 104 size PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units