Fan coil, without casing, for horizontal concealed mounting inside ceiling, bottom air intake, EC type centrifugal fan with static pressure up to 90 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection, 1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
Vai jūs interesē šis produkts? Sazinieties ar mums:

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Latvijas tirdzniecības pārstāvja vietnieks Saņemt piedāvājumu
Modelis: PS-UWLEF 4T 064
Control panels for fan coils
TER.EC.ANA Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.ANA
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.DIG Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.DIG
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.BUS Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.BUS
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.BAC Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
TER.EC.BAC
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
TEL Wireless control panel, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, possibility to connect supply hot water detection temperature sensor TM, for use with PS-CL/CLE/CLES/CLH/CLEH/CLEHS, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES, PS-DC/DCE/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory
TEL
Wireless control panel, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, possibility to connect supply hot water detection temperature sensor TM, for use with PS-CL/CLE/CLES/CLH/CLEH/CLEHS, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES, PS-DC/DCE/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory
Accessories for fan coils controls
KIT.TEL.EC Wireless control panel signal receiver and PCB together with temperature probe, for installation inside fan coil unit with EC type fan, fits to PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
KIT.TEL.EC
Wireless control panel signal receiver and PCB together with temperature probe, for installation inside fan coil unit with EC type fan, fits to PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
KIT.WI-FI.EC Electronic board for remote control of PS-FSE, PS-FLE/FLEF/FLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE fan coil units with EC type fan via Wi-Fi connection and app for smart Android / IOS devices, delivered with air temperature probe
KIT.WI-FI.EC
Electronic board for remote control of PS-FSE, PS-FLE/FLEF/FLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE fan coil units with EC type fan via Wi-Fi connection and app for smart Android / IOS devices, delivered with air temperature probe
KIT.BUS Electronic board for PS-CL/CLE/CLES/CLH/CLEH/CLQ, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DC/DCE/HDC/HDCE fan coil units connection to BMS via Mod-Bus protocol, delivered with air temperature probe
KIT.BUS
Electronic board for PS-CL/CLE/CLES/CLH/CLEH/CLQ, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DC/DCE/HDC/HDCE fan coil units connection to BMS via Mod-Bus protocol, delivered with air temperature probe
DIS.BUS Information screen to display data from device controlled via KIT.BUS electronic board
DIS.BUS
Information screen to display data from device controlled via KIT.BUS electronic board
TM Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.ANA.S / TER.ANA.S.M / TER.DIG.S / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TEL control panels
TM
Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.ANA.S / TER.ANA.S.M / TER.DIG.S / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TEL control panels
Water valves
ATT.230 On/Off actuator for water valve, powered by 230 V
ATT.230
On/Off actuator for water valve, powered by 230 V
ATT.230.M On/Off actuator for water valve, powered by 230 V, with limit switch
ATT.230.M
On/Off actuator for water valve, powered by 230 V, with limit switch
ATT.MOD Modulating by 0-10 V signal actuator for water valve
ATT.MOD
Modulating by 0-10 V signal actuator for water valve
VAL.2V.12.UWL 2-way water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 040 - 094 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for heating, 1/2" connection
VAL.2V.12.UWL
2-way water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 040 - 094 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for heating, 1/2" connection
VAL.3V.12.UWL 3-way water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 040 - 094 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for heating, 1/2" connection
VAL.3V.12.UWL
3-way water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 040 - 094 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for heating, 1/2" connection
VAL.12.DIN.UWL Balancing water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 040 - 094 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for heating, 1/2" connection
VAL.12.DIN.UWL
Balancing water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 040 - 094 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for heating, 1/2" connection
Condensate drain pumps
POM.CON.20.UWL Condensate drain pump for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, flow rate 20 l/h
POM.CON.20.UWL
Condensate drain pump for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, flow rate 20 l/h
Air inlet / outlet spigot plenums
PLE.CIR.060 Air inlet / outlet spigot plenum for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coils, quantity of spigots 2 pcs., diameter of spigots Ø150 mm
PLE.CIR.060
Air inlet / outlet spigot plenum for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coils, quantity of spigots 2 pcs., diameter of spigots Ø150 mm
Air inlet / outlet adjustable length telescopic plenums
TLDCT.060 Air inlet / outlet adjustable length telescopic plenum for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x690 mm
TLDCT.060
Air inlet / outlet adjustable length telescopic plenum for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x690 mm
Air supply grilles
GRM.060 Aluminium air supply grille with adjustable fins for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x690 mm
GRM.060
Aluminium air supply grille with adjustable fins for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x690 mm
GRMB.060 Aluminium air supply grille with fixed fins for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x690 mm
GRMB.060
Aluminium air supply grille with fixed fins for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x690 mm
Air intake grilles
GRA.060 Aluminium air intake grille for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x690 mm
GRA.060
Aluminium air intake grille for 060 / 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x690 mm
GRF.04060 Aluminium air intake grille with G3 class filter for 040 - 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 400x400 mm
GRF.04060
Aluminium air intake grille with G3 class filter for 040 - 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 400x400 mm
Antibacterial UV LED lamps
LAM.UV.LED.04060 Antibacterial UV-C LED lamp for 040 - 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units
LAM.UV.LED.04060
Antibacterial UV-C LED lamp for 040 - 064 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units
Painting in non-standard colors
GRM-V-UWL Painting of GRM / GRMB UWL air supply grille in selectable RAL color
GRM-V-UWL
Painting of GRM / GRMB UWL air supply grille in selectable RAL color
GRA-V-UWL Painting of GRA UWL air intake grille in selectable RAL color
GRA-V-UWL
Painting of GRA UWL air intake grille in selectable RAL color
GRF-V-UWL Painting of GRF UWL air intake grille in selectable RAL color
GRF-V-UWL
Painting of GRF UWL air intake grille in selectable RAL color