Fan coil, for wall mounting or standing on the floor, front air intake, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection, 1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 61 W, dimensions 1200x220xH450 mm, weight 26 kg, 2 year WARRANTY
Vai jūs interesē šis produkts? Sazinieties ar mums:

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Latvijas tirdzniecības pārstāvja vietnieks Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
PS-FL 2T - for wall mounting or standing on the floor, bottom air intake, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FL 2T 030 2.58/3.32/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 800x220xH450 mm, weight 18 kg, 2 year WARRANTY
PS-FL 2T 030
2.58/3.32/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 800x220xH450 mm, weight 18 kg, 2 year WARRANTY
PS-FL 2T 050 3.01/3.78/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 1000x220xH450 mm, weight 22 kg, 2 year WARRANTY
PS-FL 2T 050
3.01/3.78/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 1000x220xH450 mm, weight 22 kg, 2 year WARRANTY
PS-FL 2T 070 5.77/6.97/7.63 kW heating capacity or 5.15/6.05/6.53 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1200x220xH450 mm, weight 25 kg, 2 year WARRANTY
PS-FL 2T 070
5.77/6.97/7.63 kW heating capacity or 5.15/6.05/6.53 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1200x220xH450 mm, weight 25 kg, 2 year WARRANTY
PS-FL 2T 100 6.67/8.84/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 29 kg, 2 year WARRANTY
PS-FL 2T 100
6.67/8.84/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 29 kg, 2 year WARRANTY
PS-FL 2T 110 6.99/8.94/10.08 kW heating capacity or 6.77/8.53/9.52 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 31 kg, 2 year WARRANTY
PS-FL 2T 110
6.99/8.94/10.08 kW heating capacity or 6.77/8.53/9.52 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 31 kg, 2 year WARRANTY
PS-FL 4T - for wall mounting or standing on the floor, bottom air intake, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FL 4T 034 2.60/3.18/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 800x220xH450 mm, weight 19 kg, 2 year WARRANTY
PS-FL 4T 034
2.60/3.18/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 800x220xH450 mm, weight 19 kg, 2 year WARRANTY
PS-FL 4T 054 3.29/3.92/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 1000x220xH450 mm, weight 23 kg, 2 year WARRANTY
PS-FL 4T 054
3.29/3.92/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 1000x220xH450 mm, weight 23 kg, 2 year WARRANTY
PS-FL 4T 074 5.78/6.62/7.09 kW heating capacity in 1 row heat exchanger and 5.15/6.05/6.53 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1200x220xH450 mm, weight 27 kg, 2 year WARRANTY
PS-FL 4T 074
5.78/6.62/7.09 kW heating capacity in 1 row heat exchanger and 5.15/6.05/6.53 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1200x220xH450 mm, weight 27 kg, 2 year WARRANTY
PS-FL 4T 104 7.82/9.82/10.94 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 31 kg, 2 year WARRANTY
PS-FL 4T 104
7.82/9.82/10.94 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 31 kg, 2 year WARRANTY
PS-FL 4T 114 7.55/9.08/9.85 kW heating capacity in 1 row heat exchanger and 6.77/8.53/9.52 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 34 kg, 2 year WARRANTY
PS-FL 4T 114
7.55/9.08/9.85 kW heating capacity in 1 row heat exchanger and 6.77/8.53/9.52 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 34 kg, 2 year WARRANTY
PS-FLF 2T - for wall mounting or standing on the floor, front air intake, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FLF 2T 030 2.58/3.32/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 800x220xH450 mm, weight 18 kg, 2 year WARRANTY
PS-FLF 2T 030
2.58/3.32/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 800x220xH450 mm, weight 18 kg, 2 year WARRANTY
PS-FLF 2T 050 3.01/3.78/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 1000x220xH450 mm, weight 22 kg, 2 year WARRANTY
PS-FLF 2T 050
3.01/3.78/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 1000x220xH450 mm, weight 22 kg, 2 year WARRANTY
PS-FLF 2T 070 5.77/6.97/7.63 kW heating capacity or 5.15/6.05/6.53 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1200x220xH450 mm, weight 25 kg, 2 year WARRANTY
PS-FLF 2T 070
5.77/6.97/7.63 kW heating capacity or 5.15/6.05/6.53 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1200x220xH450 mm, weight 25 kg, 2 year WARRANTY
PS-FLF 2T 100 6.67/8.84/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 29 kg, 2 year WARRANTY
PS-FLF 2T 100
6.67/8.84/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 29 kg, 2 year WARRANTY
PS-FLF 2T 110 6.99/8.94/10.08 kW heating capacity or 6.77/8.53/9.52 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 31 kg, 2 year WARRANTY
PS-FLF 2T 110
6.99/8.94/10.08 kW heating capacity or 6.77/8.53/9.52 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 31 kg, 2 year WARRANTY
PS-FLF 4T - for wall mounting or standing on the floor, front air intake, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FLF 4T 034 2.60/3.18/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 800x220xH450 mm, weight 19 kg, 2 year WARRANTY
PS-FLF 4T 034
2.60/3.18/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 800x220xH450 mm, weight 19 kg, 2 year WARRANTY
PS-FLF 4T 054 3.29/3.92/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 1000x220xH450 mm, weight 23 kg, 2 year WARRANTY
PS-FLF 4T 054
3.29/3.92/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 1000x220xH450 mm, weight 23 kg, 2 year WARRANTY
PS-FLF 4T 074 5.78/6.62/7.09 kW heating capacity in 1 row heat exchanger and 5.15/6.05/6.53 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1200x220xH450 mm, weight 27 kg, 2 year WARRANTY
PS-FLF 4T 074
5.78/6.62/7.09 kW heating capacity in 1 row heat exchanger and 5.15/6.05/6.53 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1200x220xH450 mm, weight 27 kg, 2 year WARRANTY
PS-FLF 4T 104 7.82/9.82/10.94 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 31 kg, 2 year WARRANTY
PS-FLF 4T 104
7.82/9.82/10.94 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 31 kg, 2 year WARRANTY
PS-FLF 4T 114 7.55/9.08/9.85 kW heating capacity in 1 row heat exchanger and 6.77/8.53/9.52 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 34 kg, 2 year WARRANTY
PS-FLF 4T 114
7.55/9.08/9.85 kW heating capacity in 1 row heat exchanger and 6.77/8.53/9.52 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1400x220xH450 mm, weight 34 kg, 2 year WARRANTY
PS-FLE 2T - for wall mounting or standing on the floor, bottom air intake, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FLE 2T 030 1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 49 W, dimensions 800x220xH450 mm, weight 17 kg, 2 year WARRANTY
PS-FLE 2T 030
1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 49 W, dimensions 800x220xH450 mm, weight 17 kg, 2 year WARRANTY
PS-FLE 2T 050 1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 52 W, dimensions 1000x220xH450 mm, weight 21 kg, 2 year WARRANTY
PS-FLE 2T 050
1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 52 W, dimensions 1000x220xH450 mm, weight 21 kg, 2 year WARRANTY
PS-FLE 2T 070 1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 61 W, dimensions 1200x220xH450 mm, weight 24 kg, 2 year WARRANTY
PS-FLE 2T 070
1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 61 W, dimensions 1200x220xH450 mm, weight 24 kg, 2 year WARRANTY
PS-FLE 2T 100 2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 28 kg, 2 year WARRANTY
PS-FLE 2T 100
2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 28 kg, 2 year WARRANTY
PS-FLE 2T 110 3.07/6.99/10.08 kW heating capacity or 3.16/6.77/9.52 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 30 kg, 2 year WARRANTY
PS-FLE 2T 110
3.07/6.99/10.08 kW heating capacity or 3.16/6.77/9.52 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 30 kg, 2 year WARRANTY
PS-FLE 4T - for wall mounting or standing on the floor, bottom air intake, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FLE 4T 034 1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 49 W, dimensions 800x220xH450 mm, weight 18 kg, 2 year WARRANTY
PS-FLE 4T 034
1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 49 W, dimensions 800x220xH450 mm, weight 18 kg, 2 year WARRANTY
PS-FLE 4T 054 1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 52 W, dimensions 1000x220xH450 mm, weight 22 kg, 2 year WARRANTY
PS-FLE 4T 054
1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 52 W, dimensions 1000x220xH450 mm, weight 22 kg, 2 year WARRANTY
PS-FLE 4T 074 1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 61 W, dimensions 1200x220xH450 mm, weight 26 kg, 2 year WARRANTY
PS-FLE 4T 074
1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 61 W, dimensions 1200x220xH450 mm, weight 26 kg, 2 year WARRANTY
PS-FLE 4T 104 3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 30 kg, 2 year WARRANTY
PS-FLE 4T 104
3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 30 kg, 2 year WARRANTY
PS-FLE 4T 114 3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 3.16/6.77/9.52 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 33 kg, 2 year WARRANTY
PS-FLE 4T 114
3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 3.16/6.77/9.52 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 33 kg, 2 year WARRANTY
PS-FLEF 2T - for wall mounting or standing on the floor, front air intake, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FLEF 2T 030 1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 49 W, dimensions 800x220xH450 mm, weight 17 kg, 2 year WARRANTY
PS-FLEF 2T 030
1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 49 W, dimensions 800x220xH450 mm, weight 17 kg, 2 year WARRANTY
PS-FLEF 2T 050 1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 52 W, dimensions 1000x220xH450 mm, weight 21 kg, 2 year WARRANTY
PS-FLEF 2T 050
1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 52 W, dimensions 1000x220xH450 mm, weight 21 kg, 2 year WARRANTY
PS-FLEF 2T 070 1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 61 W, dimensions 1200x220xH450 mm, weight 24 kg, 2 year WARRANTY
PS-FLEF 2T 070
1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 61 W, dimensions 1200x220xH450 mm, weight 24 kg, 2 year WARRANTY
PS-FLEF 2T 100 2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 28 kg, 2 year WARRANTY
PS-FLEF 2T 100
2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 28 kg, 2 year WARRANTY
PS-FLEF 2T 110 3.07/6.99/10.08 kW heating capacity or 3.16/6.77/9.52 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 30 kg, 2 year WARRANTY
PS-FLEF 2T 110
3.07/6.99/10.08 kW heating capacity or 3.16/6.77/9.52 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 30 kg, 2 year WARRANTY
PS-FLEF 4T - for wall mounting or standing on the floor, front air intake, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FLEF 4T 034 1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 49 W, dimensions 800x220xH450 mm, weight 18 kg, 2 year WARRANTY
PS-FLEF 4T 034
1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 49 W, dimensions 800x220xH450 mm, weight 18 kg, 2 year WARRANTY
PS-FLEF 4T 054 1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 52 W, dimensions 1000x220xH450 mm, weight 22 kg, 2 year WARRANTY
PS-FLEF 4T 054
1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 52 W, dimensions 1000x220xH450 mm, weight 22 kg, 2 year WARRANTY
PS-FLEF 4T 074 1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 61 W, dimensions 1200x220xH450 mm, weight 26 kg, 2 year WARRANTY
PS-FLEF 4T 074
1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 61 W, dimensions 1200x220xH450 mm, weight 26 kg, 2 year WARRANTY
PS-FLEF 4T 104 3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 30 kg, 2 year WARRANTY
PS-FLEF 4T 104
3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 30 kg, 2 year WARRANTY
PS-FLEF 4T 114 3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 3.16/6.77/9.52 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 33 kg, 2 year WARRANTY
PS-FLEF 4T 114
3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 3.16/6.77/9.52 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 100 W, dimensions 1400x220xH450 mm, weight 33 kg, 2 year WARRANTY
PS-FL / PS-FLE / PS-FLF / PS-FLEF / PS-FLH / PS-FLEH standard fan coil units
Manuals 279 KB
Katalogi 1.5 MB
Fan coils controllers
Bukleti 8.1 MB
Modelis: PS-FLEF 4T 074
Control panels for fan coils
TER.EC.ANA Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.ANA
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.ANA.M Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for installation inside device, for use with PS-FLE/FLEF units
TER.EC.ANA.M
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for installation inside device, for use with PS-FLE/FLEF units
TER.EC.DIG Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.DIG
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.DIG.M Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for installation inside device, for use with PS-FLE/FLEF units
TER.EC.DIG.M
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for installation inside device, for use with PS-FLE/FLEF units
TER.EC.BUS Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.BUS
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.BUS.M Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for installation inside device, for use with PS-FLE/FLEF units
TER.EC.BUS.M
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for installation inside device, for use with PS-FLE/FLEF units
TER.EC.BAC Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
TER.EC.BAC
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
Accessories for fan coils controls
KIT.WI-FI.EC Electronic board for remote control of PS-FSE, PS-FLE/FLEF/FLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE fan coil units with EC type fan via Wi-Fi connection and app for smart Android / IOS devices, delivered with air temperature probe
KIT.WI-FI.EC
Electronic board for remote control of PS-FSE, PS-FLE/FLEF/FLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE fan coil units with EC type fan via Wi-Fi connection and app for smart Android / IOS devices, delivered with air temperature probe
Water valves
ATT.230 On/Off actuator for water valve, powered by 230 V
ATT.230
On/Off actuator for water valve, powered by 230 V
ATT.MOD Modulating by 0-10 V signal actuator for water valve
ATT.MOD
Modulating by 0-10 V signal actuator for water valve
VAL.2V.12.FL 2-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.2V.12.FL
2-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.3V.12.FL 3-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.3V.12.FL
3-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.12.DIN.FL Balancing water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.12.DIN.FL
Balancing water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
Condensate drain pumps
POM.CON.20.FL Condensate drain pump for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, flow rate 20 l/h
POM.CON.20.FL
Condensate drain pump for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, flow rate 20 l/h
Painting in non-standard colors
FL070.RAL Painting of casing in non-standard RAL color for 070 - 114 size PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units
FL070.RAL
Painting of casing in non-standard RAL color for 070 - 114 size PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units