Room air recirculation device with roof section, nominal air flow 12000 m³/h
Vai jūs interesē šis produkts? Sazinieties ar mums:

Roberts Priekulis

LV, RU, EN
+371 286 22395

Tirdzniecības pārstāvis Latvijā Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
Cube O - modular air heating / cooling / ventilation unit
Cube OR Room air recirculation device, nominal air flow 12000 m³/h
Cube OR
Room air recirculation device, nominal air flow 12000 m³/h
Cube ON Outside air supply device, nominal air flow 12000 m³/h
Cube ON
Outside air supply device, nominal air flow 12000 m³/h
Cube ORK Room air recirculation device with roof section, nominal air flow 12000 m³/h
Cube ORK
Room air recirculation device with roof section, nominal air flow 12000 m³/h
Cube ONK Outside air supply device with roof section, nominal air flow 12000 m³/h
Cube ONK
Outside air supply device with roof section, nominal air flow 12000 m³/h
Cube ORNK Room air recirculation and outside air supply device with roof section, nominal air flow 12000 m³/h
Cube ORNK
Room air recirculation and outside air supply device with roof section, nominal air flow 12000 m³/h
Cube O modular air heating / cooling / ventilation unit
Manuals 2.6 MB
Bukleti 2.3 MB
Presentation 15.6 MB
Modelis: Cube ORK
FLOWAIR vadības sistēma
T-box Zone Intelligent controller with touch screen, built-in room thermostat and programable week calendar, one controller can control up to 31 units, multi-zone control - can create up to 31 zones and control each unit independently, can be connected to BMS
T-box Zone
Intelligent controller with touch screen, built-in room thermostat and programable week calendar, one controller can control up to 31 units, multi-zone control - can create up to 31 zones and control each unit independently, can be connected to BMS
Gas heaters for Cube O units with roof sections
Cube OK-Gm20 Gas fired heater for Cube O unit with roof section (installed inside roof section), 4.97 - 18.18 kW modulating heat output, efficiency while working on min. - max. power %, minimum air flow 104.63 - 95.68 m³/h, max. gas (3000) consumption while working on min. - max. power G20 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 0.51 - 2.01 %, gas connection 8.8 - 9.1", weight 3/4 kg
Cube OK-Gm20
Gas fired heater for Cube O unit with roof section (installed inside roof section), 4.97 - 18.18 kW modulating heat output, efficiency while working on min. - max. power %, minimum air flow 104.63 - 95.68 m³/h, max. gas (3000) consumption while working on min. - max. power G20 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 0.51 - 2.01 %, gas connection 8.8 - 9.1", weight 3/4 kg
Cube OK-Gm34 Gas fired heater for Cube O unit with roof section (installed inside roof section), 8.13 - 33.56 kW modulating heat output, efficiency while working on min. - max. power %, minimum air flow 106.97 - 96.30 m³/h, max. gas (3500) consumption while working on min. - max. power G20 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 0.80 - 3.69 %, gas connection 8.7 - 9.1", weight 3/4 kg
Cube OK-Gm34
Gas fired heater for Cube O unit with roof section (installed inside roof section), 8.13 - 33.56 kW modulating heat output, efficiency while working on min. - max. power %, minimum air flow 106.97 - 96.30 m³/h, max. gas (3500) consumption while working on min. - max. power G20 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 0.80 - 3.69 %, gas connection 8.7 - 9.1", weight 3/4 kg
Cube OK-Gm45 Gas fired heater for Cube O unit with roof section (installed inside roof section), 8.97 - 40.45 kW modulating heat output, efficiency while working on min. - max. power %, minimum air flow 105.50 - 96.30 m³/h, max. gas (4200) consumption while working on min. - max. power G20 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 0.90 - 4.44 %, gas connection 8.7 - 9.1", weight 3/4 kg
Cube OK-Gm45
Gas fired heater for Cube O unit with roof section (installed inside roof section), 8.97 - 40.45 kW modulating heat output, efficiency while working on min. - max. power %, minimum air flow 105.50 - 96.30 m³/h, max. gas (4200) consumption while working on min. - max. power G20 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 0.90 - 4.44 %, gas connection 8.7 - 9.1", weight 3/4 kg
Cube OK-Gm65 Gas fired heater for Cube O unit with roof section (installed inside roof section), 13.40 - 62.93 kW modulating heat output, efficiency while working on min. - max. power %, minimum air flow 108.06 - 96.82 m³/h, max. gas (6500) consumption while working on min. - max. power G20 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 1.31 - 6.88 %, gas connection 8.7 - 9.1", weight 3/4 kg
Cube OK-Gm65
Gas fired heater for Cube O unit with roof section (installed inside roof section), 13.40 - 62.93 kW modulating heat output, efficiency while working on min. - max. power %, minimum air flow 108.06 - 96.82 m³/h, max. gas (6500) consumption while working on min. - max. power G20 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 1.31 - 6.88 %, gas connection 8.7 - 9.1", weight 3/4 kg
Water heat exchangers sections for Cube O units
Cube O-W2 Water heater section for Cube O unit, two row heat exchanger, 14.0-68.3 kW heating capacity at 70/50°C water and 8°C air temperatures, 1" water connection
Cube O-W2
Water heater section for Cube O unit, two row heat exchanger, 14.0-68.3 kW heating capacity at 70/50°C water and 8°C air temperatures, 1" water connection
Cube O-W3 Water heater section for Cube O unit, three row heat exchanger, 16.8-100.8 kW heating capacity at 70/50°C water and 8°C air temperatures, 1" water connection
Cube O-W3
Water heater section for Cube O unit, three row heat exchanger, 16.8-100.8 kW heating capacity at 70/50°C water and 8°C air temperatures, 1" water connection
Cube O-C2 Water cooler / heater section for Cube O unit, two row heat exchanger, 10.0-22.7 kW cooling capacity at 7/12°C water and 26°C air temperatures, 14.0-68.3 kW heating capacity at 70/50°C water and 8°C air temperatures, 1" water connection
Cube O-C2
Water cooler / heater section for Cube O unit, two row heat exchanger, 10.0-22.7 kW cooling capacity at 7/12°C water and 26°C air temperatures, 14.0-68.3 kW heating capacity at 70/50°C water and 8°C air temperatures, 1" water connection
Cube O-C3 Water cooler / heater section for Cube O unit, three row heat exchanger, 14.4-33.4 kW cooling capacity at 7/12°C water and 26°C air temperatures, 16.8-100.8 kW heating capacity at 70/50°C water and 8°C air temperatures, 1" water connection
Cube O-C3
Water cooler / heater section for Cube O unit, three row heat exchanger, 14.4-33.4 kW cooling capacity at 7/12°C water and 26°C air temperatures, 16.8-100.8 kW heating capacity at 70/50°C water and 8°C air temperatures, 1" water connection
Electric heaters sections for Cube O units
Cube O-E Electric heater section for Cube O unit, ? kW heating power, ? heating steps
Cube O-E
Electric heater section for Cube O unit, ? kW heating power, ? heating steps
Fans for Cube O units with roof sections
Cube OK-P1 Radial type EC fan for Cube O unit with roof section, size 1
Cube OK-P1
Radial type EC fan for Cube O unit with roof section, size 1
Cube OK-P2 Radial type EC fan for Cube O unit with roof section, size 2
Cube OK-P2
Radial type EC fan for Cube O unit with roof section, size 2
Cube OK-P3 Radial type EC fan for Cube O unit with roof section, size 3
Cube OK-P3
Radial type EC fan for Cube O unit with roof section, size 3
Cube OK-P4 Radial type EC fan for Cube O unit with roof section, size 4
Cube OK-P4
Radial type EC fan for Cube O unit with roof section, size 4
Air filters for Cube O units with roof sections
Cube OK-F-G4 Air filter for Cube O unit with roof section, filter type Coarse 80% (~G4)
Cube OK-F-G4
Air filter for Cube O unit with roof section, filter type Coarse 80% (~G4)
Cube OK-F-F7 Air filter for Cube O unit with roof section, filter type ePM2.5 65% (~F7)
Cube OK-F-F7
Air filter for Cube O unit with roof section, filter type ePM2.5 65% (~F7)
Cube OK-F-M5 Air filter for Cube O unit with roof section, filter type ePM10 50% (~M5)
Cube OK-F-M5
Air filter for Cube O unit with roof section, filter type ePM10 50% (~M5)
Air supply modules for Cube O units
Cube O-D Air supply module with swirl diffuser controlled by electric actuator for Cube O unit
Cube O-D
Air supply module with swirl diffuser controlled by electric actuator for Cube O unit
Cube O-V4 Air supply module with 4 pcs. of ventilation ducts connections, for Cube O unit
Cube O-V4
Air supply module with 4 pcs. of ventilation ducts connections, for Cube O unit
Cube O-V3 Air supply module with 3 pcs. of ventilation ducts connections, for Cube O unit
Cube O-V3
Air supply module with 3 pcs. of ventilation ducts connections, for Cube O unit
Cube O-V2 Air supply module with 2 pcs. of ventilation ducts connections, for Cube O unit
Cube O-V2
Air supply module with 2 pcs. of ventilation ducts connections, for Cube O unit
Cube O-V1 Air supply module with 1 pcs. of ventilation ducts connections, for Cube O unit
Cube O-V1
Air supply module with 1 pcs. of ventilation ducts connections, for Cube O unit
Cube O-J4 Air supply module with 4 pcs. of long range nozzles, for Cube O unit
Cube O-J4
Air supply module with 4 pcs. of long range nozzles, for Cube O unit
Cube O-J3 Air supply module with 3 pcs. of long range nozzles, for Cube O unit
Cube O-J3
Air supply module with 3 pcs. of long range nozzles, for Cube O unit
Cube O-J2 Air supply module with 2 pcs. of long range nozzles, for Cube O unit
Cube O-J2
Air supply module with 2 pcs. of long range nozzles, for Cube O unit
Cube O-J1 Air supply module with 1 pcs. of long range nozzles, for Cube O unit
Cube O-J1
Air supply module with 1 pcs. of long range nozzles, for Cube O unit