Gas absorption heat pump, takes heat from Air and gives it to Water for heating or domestic hot water production, maximum outlet water temperature for heating/DHW 65/70°C, heating capacity 41.3 kW (A7/W35), G.U.E. gas utilization efficiency 164% (A7/W35), A+ energy class ErP on 55°C operation, gas (G20) consumption 2.67 m³/h, electrical power consumption 0.84 kW, sound pressure level (at 5 m distance) 57.6 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 390 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C
Vai jūs interesē šis produkts? Sazinieties ar mums:

Roberts Priekulis

LV, RU, EN
+371 286 22395

Tirdzniecības pārstāvis Latvijā Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
GAHP-A - takes heat from Air and gives it to Water for heating or domestic hot water production
GAHP-A STANDARD Maximum outlet water temperature for heating/DHW 65/70°C, heating capacity 41.3 kW (A7/W35), G.U.E. gas utilization efficiency 164% (A7/W35), A+ energy class ErP on 55°C operation, gas (G20) consumption 2.67 m³/h, electrical power consumption 0.84 kW, sound pressure level (at 5 m distance) 57.6 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 390 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C
GAHP-A STANDARD
Maximum outlet water temperature for heating/DHW 65/70°C, heating capacity 41.3 kW (A7/W35), G.U.E. gas utilization efficiency 164% (A7/W35), A+ energy class ErP on 55°C operation, gas (G20) consumption 2.67 m³/h, electrical power consumption 0.84 kW, sound pressure level (at 5 m distance) 57.6 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 390 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C
GAHP-A LOW-NOISE Maximum outlet water temperature for heating/DHW 65/70°C, heating capacity 41.3 kW (A7/W35), G.U.E. gas utilization efficiency 164% (A7/W35), A+ energy class ErP on 55°C operation, gas (G20) consumption 2.67 m³/h, electrical power consumption while fan working on min/max speed 0.50/0.77 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49/52 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 400 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C
GAHP-A LOW-NOISE
Maximum outlet water temperature for heating/DHW 65/70°C, heating capacity 41.3 kW (A7/W35), G.U.E. gas utilization efficiency 164% (A7/W35), A+ energy class ErP on 55°C operation, gas (G20) consumption 2.67 m³/h, electrical power consumption while fan working on min/max speed 0.50/0.77 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49/52 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 400 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C
Modelis: GAHP-A STANDARD
Heating operation mode data
Energy class (55°C operation)
ErP
A+
G.U.E. gas utilization efficiency at 35°C water and 7°C air temperature
%
164
Heating capacity at 35°C water and 7°C air temperature
kW
41,3
G.U.E. gas utilization efficiency at 50°C water and 7°C air temperature
%
152
Heating capacity at 50°C water and 7°C air temperature
kW
38,3
Nominal water flow rate (ΔT = 10°C)
m³/h
3,0
Nominal water pressure loss (outlet water at 50°C)
kPa
43
Maximum outlet water temperature (heating / DHW)
°C
+65 / +70
Maximum inlet water temperature (heating / DHW)
°C
+55 / +60
Darba vides temperatūras intervāls
°C
-15 / +40
Operating temperature range with winter kit
°C
-30 / +40
Burner characteristics
Thermal input (actual)
kW
25,2
Dabasgāzes (G20) patēriņš pie 15 °C - 1013 mbar
m³/st.
2,67
Sašķidrinātas gāzes (LPG G30 / G31) patēriņš pie 15 °C - 1013 mbar
kg/h
1,99 / 1,96
Instalācijas dati
Elektrības padeve
V/Hz
230/50
Nominal electrical power consumption
kW
0,84
Sound pressure at 5 meters distance from unit front side in free field
dB(A)
57,6
IP aizsardzības klase
X5D
Ūdens cauruļu pievienošana
Ø "
F 1 1/4
Gāzes savienojums
Ø "
F 3/4
Exhaust air flue diameter
mm Ø
80
Izmēri
Platums
mm
854
Dziļums
mm
1260
Augstums
mm
1445
Svars
kg
390

Izmēri

Modelis: GAHP-A STANDARD
GAHP-A gas absorption heat pump Air/Water
Manuals 7.4 MB
Atbilstības deklarācijas 5.7 MB
Katalogi 3.5 MB
Sildīšanas jaudas tabulas 974 KB
BIM objects 13.8 MB
Comfort Control Interface installation and use manual 798 KB
Multiple preassembled groups (Link) installation, user and maintenance manual 15 MB
DDC control panel
Manuals 12.4 MB
Bukleti 795 KB
MODBUS protocol for connection to BMS 690 KB
RB100 (Robur Box 100) control interface
Manuals 3.1 MB
RB200 (Robur Box 200) control interface
Manuals 3.1 MB
Modelis: GAHP-A STANDARD
Additional accessories for GAHP gas absorption heat pumps and AY boilers
OCRM009 Control panel DDC for configuring AY boilers, RTY links of those boilers, gas heat pumps
OCRM009
Control panel DDC for configuring AY boilers, RTY links of those boilers, gas heat pumps
ODSP014 RB100 (Robur Box 100) control system for Robur gas absorption heat pumps fitted with Direct Digital Control (DDC). Main functions: heating, DHW and cooling mode management; 3-way valve management for switching heating and DHW; control and error alarm.
ODSP014
RB100 (Robur Box 100) control system for Robur gas absorption heat pumps fitted with Direct Digital Control (DDC). Main functions: heating, DHW and cooling mode management; 3-way valve management for switching heating and DHW; control and error alarm.
ODSP023 RB200 (Robur Box 200) control system for Robur gas absorption heat pumps fitted with Direct Digital Control (DDC). Main functions: integration of third parties appliances, i.e. in case of retrofitting of existing systems; control of water circulation of primary and secondary circuits; 3-way valve management for switching heating and DHW; control and error alarm.
ODSP023
RB200 (Robur Box 200) control system for Robur gas absorption heat pumps fitted with Direct Digital Control (DDC). Main functions: integration of third parties appliances, i.e. in case of retrofitting of existing systems; control of water circulation of primary and secondary circuits; 3-way valve management for switching heating and DHW; control and error alarm.
OKBT011 Special GAHP-A / GAHP-GS gas absorbtion heat pump winter kit, required if ambient temperature in winter gets lower than -15°C, with this protection unit can work till -30°C ambient temperature, it must be installed at the installation site
OKBT011
Special GAHP-A / GAHP-GS gas absorbtion heat pump winter kit, required if ambient temperature in winter gets lower than -15°C, with this protection unit can work till -30°C ambient temperature, it must be installed at the installation site
OSND007 Outdoor air temperature probe for DDC control panel
OSND007
Outdoor air temperature probe for DDC control panel
OSND004 Immersion temperature proble
OSND004
Immersion temperature proble
OPMP008 Water pump WILO STRATOS PARA 25-12 for use with gas absorption heat pumps
OPMP008
Water pump WILO STRATOS PARA 25-12 for use with gas absorption heat pumps
ODSP033 Roburberry microcomputer for remote monitoring and control of devices, connects to the DDC control panel via RS485 port
ODSP033
Roburberry microcomputer for remote monitoring and control of devices, connects to the DDC control panel via RS485 port
ODSP052 GSM modem for Roburberry microcomputer
ODSP052
GSM modem for Roburberry microcomputer
RBCLOUD2Y 2-year free connection of the Roburberry microcomputer to the Robur Cloud remote device monitoring and control system
RBCLOUD2Y
2-year free connection of the Roburberry microcomputer to the Robur Cloud remote device monitoring and control system
Antivibration spring kits for GAHP gas absorption heat pumps and AY boilers
ONTV012 Antivibration springs kit for single GAHP gas absorption heat pump or single AY gas boiler, consists of 4 pcs. of springs, recommended to use when installing unit inside building or on the roof
ONTV012
Antivibration springs kit for single GAHP gas absorption heat pump or single AY gas boiler, consists of 4 pcs. of springs, recommended to use when installing unit inside building or on the roof