Fan coil, cassette, for mounting to the suspended ceiling, three-speed AC type ebm‑papst fan, galvanized steel casing with anti-condensation coating and sound-absorbing material, integrated condensate pump, G3 class air filter, RAL9003 white ABS plastic diffuser, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection, 4.06/4.50/7.15 kW heating capacity or 3.64/3.99/6.16 kW cooling capacity in 4 row heat exchanger, air flow 430/480/800 m³/h, sound pressure level 31/37/45 dB(A), max. fan power 75 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
Vai jūs interesē šis produkts? Sazinieties ar mums:

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Latvijas tirdzniecības pārstāvja vietnieks Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
PS-CL 2T - cassette, for mounting to the suspended ceiling, three-speed AC type ebm‑papst fan, galvanized steel casing with anti-condensation coating and sound-absorbing material, integrated condensate pump, G3 class air filter, RAL9003 white ABS plastic diffuser, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-CL 2T 050/2R 2.42/2.72/3.41 kW heating capacity or 1.45/1.56/2.39 kW cooling capacity in 2 row heat exchanger, air flow 340/400/500 m³/h, sound pressure level 23/32/39 dB(A), max. fan power 35 W, ceiling hole 600x600xH250 mm, weight 18 kg, 2 year WARRANTY
PS-CL 2T 050/2R
2.42/2.72/3.41 kW heating capacity or 1.45/1.56/2.39 kW cooling capacity in 2 row heat exchanger, air flow 340/400/500 m³/h, sound pressure level 23/32/39 dB(A), max. fan power 35 W, ceiling hole 600x600xH250 mm, weight 18 kg, 2 year WARRANTY
PS-CL 2T 070/2R 2.45/3.47/4.78 kW heating capacity or 1.48/2.47/3.51 kW cooling capacity in 2 row heat exchanger, air flow 340/500/750 m³/h, sound pressure level 24/36/44 dB(A), max. fan power 63 W, ceiling hole 600x600xH250 mm, weight 18 kg, 2 year WARRANTY
PS-CL 2T 070/2R
2.45/3.47/4.78 kW heating capacity or 1.48/2.47/3.51 kW cooling capacity in 2 row heat exchanger, air flow 340/500/750 m³/h, sound pressure level 24/36/44 dB(A), max. fan power 63 W, ceiling hole 600x600xH250 mm, weight 18 kg, 2 year WARRANTY
PS-CL 2T 080/3R 3.69/4.06/6.25 kW heating capacity or 2.98/3.29/5.06 kW cooling capacity in 3 row heat exchanger, air flow 430/480/800 m³/h, sound pressure level 31/37/45 dB(A), max. fan power 75 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CL 2T 080/3R
3.69/4.06/6.25 kW heating capacity or 2.98/3.29/5.06 kW cooling capacity in 3 row heat exchanger, air flow 430/480/800 m³/h, sound pressure level 31/37/45 dB(A), max. fan power 75 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CL 2T 090/3R 3.73/5.04/7.03 kW heating capacity or 3.04/4.13/5.72 kW cooling capacity in 3 row heat exchanger, air flow 430/610/910 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 78 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CL 2T 090/3R
3.73/5.04/7.03 kW heating capacity or 3.04/4.13/5.72 kW cooling capacity in 3 row heat exchanger, air flow 430/610/910 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 78 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CL 2T 080/4R 4.06/4.50/7.15 kW heating capacity or 3.64/3.99/6.16 kW cooling capacity in 4 row heat exchanger, air flow 430/480/800 m³/h, sound pressure level 31/37/45 dB(A), max. fan power 75 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CL 2T 080/4R
4.06/4.50/7.15 kW heating capacity or 3.64/3.99/6.16 kW cooling capacity in 4 row heat exchanger, air flow 430/480/800 m³/h, sound pressure level 31/37/45 dB(A), max. fan power 75 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CL 2T 090/4R 4.07/5.62/8.06 kW heating capacity or 3.61/4.87/6.84 kW cooling capacity in 4 row heat exchanger, air flow 430/610/910 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 78 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CL 2T 090/4R
4.07/5.62/8.06 kW heating capacity or 3.61/4.87/6.84 kW cooling capacity in 4 row heat exchanger, air flow 430/610/910 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 78 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CL 2T 100/3R 6.42/6.95/8.43 kW heating capacity or 5.55/5.99/7.21 kW cooling capacity in 3 row heat exchanger, air flow 730/800/1000 m³/h, sound pressure level 26/32/41 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 2T 100/3R
6.42/6.95/8.43 kW heating capacity or 5.55/5.99/7.21 kW cooling capacity in 3 row heat exchanger, air flow 730/800/1000 m³/h, sound pressure level 26/32/41 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 2T 120/3R 7.03/8.53/10.46 kW heating capacity or 6.01/7.26/8.83 kW cooling capacity in 3 row heat exchanger, air flow 800/1000/1270 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 110 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 2T 120/3R
7.03/8.53/10.46 kW heating capacity or 6.01/7.26/8.83 kW cooling capacity in 3 row heat exchanger, air flow 800/1000/1270 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 110 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 2T 150/3R 7.42/9.49/12.72 kW heating capacity or 6.47/8.21/10.85 kW cooling capacity in 3 row heat exchanger, air flow 830/1100/1550 m³/h, sound pressure level 33/45/51 dB(A), max. fan power 150 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 2T 150/3R
7.42/9.49/12.72 kW heating capacity or 6.47/8.21/10.85 kW cooling capacity in 3 row heat exchanger, air flow 830/1100/1550 m³/h, sound pressure level 33/45/51 dB(A), max. fan power 150 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 2T 150/4R 7.98/10.38/14.22 kW heating capacity or 7.52/9.63/12.99 kW cooling capacity in 4 row heat exchanger, air flow 830/1100/1550 m³/h, sound pressure level 33/45/51 dB(A), max. fan power 150 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 2T 150/4R
7.98/10.38/14.22 kW heating capacity or 7.52/9.63/12.99 kW cooling capacity in 4 row heat exchanger, air flow 830/1100/1550 m³/h, sound pressure level 33/45/51 dB(A), max. fan power 150 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 4T - cassette, for mounting to the suspended ceiling, three-speed AC type ebm‑papst fan, galvanized steel casing with anti-condensation coating and sound-absorbing material, integrated condensate pump, G3 class air filter, RAL9003 white ABS plastic diffuser, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-CL 4T 054/2R+1 3.31/3.66/4.77 kW heating capacity in 1 row heat exchanger and 2.01/2.23/2.97 kW cooling capacity in 2 row heat exchanger, air flow 340/390/570 m³/h, sound pressure level 23/32/39 dB(A), max. fan power 35 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CL 4T 054/2R+1
3.31/3.66/4.77 kW heating capacity in 1 row heat exchanger and 2.01/2.23/2.97 kW cooling capacity in 2 row heat exchanger, air flow 340/390/570 m³/h, sound pressure level 23/32/39 dB(A), max. fan power 35 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CL 4T 084/2R+1 4.06/4.39/6.27 kW heating capacity in 1 row heat exchanger and 2.58/2.80/4.08 kW cooling capacity in 2 row heat exchanger, air flow 430/480/800 m³/h, sound pressure level 31/37/45 dB(A), max. fan power 75 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CL 4T 084/2R+1
4.06/4.39/6.27 kW heating capacity in 1 row heat exchanger and 2.58/2.80/4.08 kW cooling capacity in 2 row heat exchanger, air flow 430/480/800 m³/h, sound pressure level 31/37/45 dB(A), max. fan power 75 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CL 4T 094/2R+1 4.06/5.19/6.84 kW heating capacity in 1 row heat exchanger and 2.57/3.38/4.56 kW cooling capacity in 2 row heat exchanger, air flow 430/610/910 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 78 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CL 4T 094/2R+1
4.06/5.19/6.84 kW heating capacity in 1 row heat exchanger and 2.57/3.38/4.56 kW cooling capacity in 2 row heat exchanger, air flow 430/610/910 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 78 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CL 4T 094/3R+1 4.06/5.19/6.84 kW heating capacity in 1 row heat exchanger and 3.03/4.13/5.72 kW cooling capacity in 3 row heat exchanger, air flow 430/610/910 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 78 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CL 4T 094/3R+1
4.06/5.19/6.84 kW heating capacity in 1 row heat exchanger and 3.03/4.13/5.72 kW cooling capacity in 3 row heat exchanger, air flow 430/610/910 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 78 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CL 4T 124/2R+1 7.43/8.69/10.26 kW heating capacity in 1 row heat exchanger and 4.90/5.80/6.93 kW cooling capacity in 2 row heat exchanger, air flow 800/1000/1270 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 110 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 4T 124/2R+1
7.43/8.69/10.26 kW heating capacity in 1 row heat exchanger and 4.90/5.80/6.93 kW cooling capacity in 2 row heat exchanger, air flow 800/1000/1270 m³/h, sound pressure level 32/41/47 dB(A), max. fan power 110 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 4T 154/2R+1 7.87/9.06/12.17 kW heating capacity in 1 row heat exchanger and 5.38/6.66/8.59 kW cooling capacity in 2 row heat exchanger, air flow 830/1100/1550 m³/h, sound pressure level 33/45/51 dB(A), max. fan power 150 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 4T 154/2R+1
7.87/9.06/12.17 kW heating capacity in 1 row heat exchanger and 5.38/6.66/8.59 kW cooling capacity in 2 row heat exchanger, air flow 830/1100/1550 m³/h, sound pressure level 33/45/51 dB(A), max. fan power 150 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 4T 154/3R+1 7.87/9.60/12.17 kW heating capacity in 1 row heat exchanger and 6.50/8.21/10.82 kW cooling capacity in 3 row heat exchanger, air flow 830/1100/1550 m³/h, sound pressure level 33/45/51 dB(A), max. fan power 150 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL 4T 154/3R+1
7.87/9.60/12.17 kW heating capacity in 1 row heat exchanger and 6.50/8.21/10.82 kW cooling capacity in 3 row heat exchanger, air flow 830/1100/1550 m³/h, sound pressure level 33/45/51 dB(A), max. fan power 150 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLE 2T - cassette, for mounting to the suspended ceiling, EC type ebm‑papst fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel casing with anti-condensation coating and sound-absorbing material, integrated condensate pump, G3 class air filter, RAL9003 white ABS plastic diffuser, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-CLE 2T 070/2R 1.94/3.96/5.85 kW heating capacity or 1.27/2.88/4.32 kW cooling capacity in 2 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 41 W, ceiling hole 600x600xH250 mm, weight 18 kg, 2 year WARRANTY
PS-CLE 2T 070/2R
1.94/3.96/5.85 kW heating capacity or 1.27/2.88/4.32 kW cooling capacity in 2 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 41 W, ceiling hole 600x600xH250 mm, weight 18 kg, 2 year WARRANTY
PS-CLE 2T 090/3R 2.29/4.90/7.47 kW heating capacity or 1.89/4.01/6.07 kW cooling capacity in 3 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 45 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CLE 2T 090/3R
2.29/4.90/7.47 kW heating capacity or 1.89/4.01/6.07 kW cooling capacity in 3 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 45 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CLE 2T 090/4R 2.43/5.46/8.60 kW heating capacity or 2.17/4.74/7.29 kW cooling capacity in 4 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 45 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CLE 2T 090/4R
2.43/5.46/8.60 kW heating capacity or 2.17/4.74/7.29 kW cooling capacity in 4 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 45 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CLE 2T 150/3R 7.34/11.39/13.20 kW heating capacity or 6.41/9.77/11.24 kW cooling capacity in 3 row heat exchanger, air flow 820/1360/1620 m³/h, sound pressure level 26/44/51 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLE 2T 150/3R
7.34/11.39/13.20 kW heating capacity or 6.41/9.77/11.24 kW cooling capacity in 3 row heat exchanger, air flow 820/1360/1620 m³/h, sound pressure level 26/44/51 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLE 2T 150/4R 7.88/12.63/14.80 kW heating capacity or 7.44/11.60/13.49 kW cooling capacity in 4 row heat exchanger, air flow 820/1360/1620 m³/h, sound pressure level 26/44/51 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLE 2T 150/4R
7.88/12.63/14.80 kW heating capacity or 7.44/11.60/13.49 kW cooling capacity in 4 row heat exchanger, air flow 820/1360/1620 m³/h, sound pressure level 26/44/51 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLE 4T - cassette, for mounting to the suspended ceiling, EC type ebm‑papst fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel casing with anti-condensation coating and sound-absorbing material, integrated condensate pump, G3 class air filter, RAL9003 white ABS plastic diffuser, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-CLE 4T 094/2R+1 2.73/5.08/7.19 kW heating capacity in 1 row heat exchanger and 1.58/3.30/4.82 kW cooling capacity in 2 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 45 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CLE 4T 094/2R+1
2.73/5.08/7.19 kW heating capacity in 1 row heat exchanger and 1.58/3.30/4.82 kW cooling capacity in 2 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 45 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CLE 4T 094/3R+1 2.73/5.08/7.19 kW heating capacity in 1 row heat exchanger and 2.05/4.26/6.39 kW cooling capacity in 3 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 45 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CLE 4T 094/3R+1
2.73/5.08/7.19 kW heating capacity in 1 row heat exchanger and 2.05/4.26/6.39 kW cooling capacity in 3 row heat exchanger, air flow 250/590/980 m³/h, sound pressure level 18/34/48 dB(A), max. fan power 45 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CLE 4T 154/2R+1 7.80/11.12/12.54 kW heating capacity in 1 row heat exchanger and 5.33/7.80/8.87 kW cooling capacity in 2 row heat exchanger, air flow 820/1360/1620 m³/h, sound pressure level 26/44/51 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLE 4T 154/2R+1
7.80/11.12/12.54 kW heating capacity in 1 row heat exchanger and 5.33/7.80/8.87 kW cooling capacity in 2 row heat exchanger, air flow 820/1360/1620 m³/h, sound pressure level 26/44/51 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLE 4T 154/3R+1 7.80/11.12/12.54 kW heating capacity in 1 row heat exchanger and 6.43/9.75/11.20 kW cooling capacity in 3 row heat exchanger, air flow 820/1360/1620 m³/h, sound pressure level 26/44/51 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLE 4T 154/3R+1
7.80/11.12/12.54 kW heating capacity in 1 row heat exchanger and 6.43/9.75/11.20 kW cooling capacity in 3 row heat exchanger, air flow 820/1360/1620 m³/h, sound pressure level 26/44/51 dB(A), max. fan power 85 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLES 2T - cassette, for mounting to the suspended ceiling, silenced version for places that require a low noise level, EC type ebm‑papst fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel casing with anti-condensation coating and sound-absorbing material, integrated condensate pump, G3 class air filter, RAL9003 white ABS plastic diffuser, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-CLES 2T 070/2R 1.43/3.46/4.77 kW heating capacity or 0.96/2.54/3.56 kW cooling capacity in 2 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 18 kg, 2 year WARRANTY
PS-CLES 2T 070/2R
1.43/3.46/4.77 kW heating capacity or 0.96/2.54/3.56 kW cooling capacity in 2 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 18 kg, 2 year WARRANTY
PS-CLES 2T 090/3R 1.66/4.20/5.90 kW heating capacity or 1.39/3.47/4.87 kW cooling capacity in 3 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CLES 2T 090/3R
1.66/4.20/5.90 kW heating capacity or 1.39/3.47/4.87 kW cooling capacity in 3 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CLES 2T 090/4R 1.75/4.66/6.71 kW heating capacity or 1.58/4.10/5.78 kW cooling capacity in 4 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CLES 2T 090/4R
1.75/4.66/6.71 kW heating capacity or 1.58/4.10/5.78 kW cooling capacity in 4 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 19 kg, 2 year WARRANTY
PS-CLES 2T 150/3R 4.49/8.32/11.37 kW heating capacity or 4.06/7.33/9.84 kW cooling capacity in 3 row heat exchanger, air flow 480/940/1350 m³/h, sound pressure level 18/30/44 dB(A), max. fan power 65 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLES 2T 150/3R
4.49/8.32/11.37 kW heating capacity or 4.06/7.33/9.84 kW cooling capacity in 3 row heat exchanger, air flow 480/940/1350 m³/h, sound pressure level 18/30/44 dB(A), max. fan power 65 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLES 2T 150/4R 4.73/9.11/12.63 kW heating capacity or 4.66/8.59/11.67 kW cooling capacity in 4 row heat exchanger, air flow 480/940/1350 m³/h, sound pressure level 18/30/44 dB(A), max. fan power 65 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLES 2T 150/4R
4.73/9.11/12.63 kW heating capacity or 4.66/8.59/11.67 kW cooling capacity in 4 row heat exchanger, air flow 480/940/1350 m³/h, sound pressure level 18/30/44 dB(A), max. fan power 65 W, ceiling hole 1200x600xH250 mm, weight 38 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLES 4T - cassette, for mounting to the suspended ceiling, silenced version for places that require a low noise level, EC type ebm‑papst fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel casing with anti-condensation coating and sound-absorbing material, integrated condensate pump, G3 class air filter, RAL9003 white ABS plastic diffuser, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-CLES 4T 094/2R+1 2.13/4.54/6.14 kW heating capacity in 1 row heat exchanger and 1.16/2.86/3.87 kW cooling capacity in 2 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CLES 4T 094/2R+1
2.13/4.54/6.14 kW heating capacity in 1 row heat exchanger and 1.16/2.86/3.87 kW cooling capacity in 2 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CLES 4T 094/3R+1 2.13/4.54/6.14 kW heating capacity in 1 row heat exchanger and 1.49/3.68/5.06 kW cooling capacity in 3 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CLES 4T 094/3R+1
2.13/4.54/6.14 kW heating capacity in 1 row heat exchanger and 1.49/3.68/5.06 kW cooling capacity in 3 row heat exchanger, air flow 180/500/750 m³/h, sound pressure level 16/29/41 dB(A), max. fan power 34 W, ceiling hole 600x600xH250 mm, weight 19.5 kg, 2 year WARRANTY
PS-CLES 4T 154/2R+1 5.40/8.80/11.42 kW heating capacity in 1 row heat exchanger and 3.38/5.85/7.77 kW cooling capacity in 2 row heat exchanger, air flow 480/940/1350 m³/h, sound pressure level 18/30/44 dB(A), max. fan power 65 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLES 4T 154/2R+1
5.40/8.80/11.42 kW heating capacity in 1 row heat exchanger and 3.38/5.85/7.77 kW cooling capacity in 2 row heat exchanger, air flow 480/940/1350 m³/h, sound pressure level 18/30/44 dB(A), max. fan power 65 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLES 4T 154/3R+1 5.40/8.79/11.42 kW heating capacity in 1 row heat exchanger and 4.03/7.22/9.69 kW cooling capacity in 3 row heat exchanger, air flow 480/940/1350 m³/h, sound pressure level 18/30/44 dB(A), max. fan power 65 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CLES 4T 154/3R+1
5.40/8.79/11.42 kW heating capacity in 1 row heat exchanger and 4.03/7.22/9.69 kW cooling capacity in 3 row heat exchanger, air flow 480/940/1350 m³/h, sound pressure level 18/30/44 dB(A), max. fan power 65 W, ceiling hole 1200x600xH250 mm, weight 39 kg, delivered with auxiliary drain pan for valve, 2 year WARRANTY
PS-CL / PS-CLE cassette fan coil units
Manuals 3.2 MB
Bukleti 2.3 MB
Katalogi 3.3 MB
Tehniskie dati 6 MB
PS-CLES silenced version of cassette fan coil units
Manuals 3.2 MB
Bukleti 2.1 MB
TEL wireless remote control panel
Manuals 254 KB
Fan coils controllers
Bukleti 8.1 MB
Modelis: PS-CL 2T 080/4R
Control panels for fan coils
TER.ANA Suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.ANA
Suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.ANA.S Suitable for 2-pipe and 4-pipe units with AC fans, automatic 3 steps fan speed selection, integrated thermostat, possibility to remotely turn device on/off, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units without valves
TER.ANA.S
Suitable for 2-pipe and 4-pipe units with AC fans, automatic 3 steps fan speed selection, integrated thermostat, possibility to remotely turn device on/off, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units without valves
TER.DIG Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.DIG
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.DIG.D Suitable for 2-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, for use with PS-FS, PS-FL/FLF/FLH 2T, PS-CL/CLH 2T, PS-UWL/UWLF/UWLV 2T, PS-DC/HDC 2T units
TER.DIG.D
Suitable for 2-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, for use with PS-FS, PS-FL/FLF/FLH 2T, PS-CL/CLH 2T, PS-UWL/UWLF/UWLV 2T, PS-DC/HDC 2T units
TER.DIG.S Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to control additional electric heater, on/off valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.DIG.S
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to control additional electric heater, on/off valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BUS Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BUS
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BAC Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BAC
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.TOUCH Suitable for 2-pipe units with AC fans, touch screen, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, programmable weekly calendar, on/off valves control, possibility to connect remote air sensor SM, Wi-Fi connection for possibility to control the device remotely through the app for smart Android / IOS devices, for use with PS-FS, PS-FL/FLF/FLH 2T, PS-CL/CLH 2T, PS-UWL/UWLF/UWLV 2T, PS-DC/HDC 2T units
TER.TOUCH
Suitable for 2-pipe units with AC fans, touch screen, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, programmable weekly calendar, on/off valves control, possibility to connect remote air sensor SM, Wi-Fi connection for possibility to control the device remotely through the app for smart Android / IOS devices, for use with PS-FS, PS-FL/FLF/FLH 2T, PS-CL/CLH 2T, PS-UWL/UWLF/UWLV 2T, PS-DC/HDC 2T units
TEL Wireless, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, possibility to connect supply hot water detection temperature sensor TM, for use with PS-CL/CLE/CLES/CLH/CLEH, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES, PS-DC/DCE/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory
TEL
Wireless, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, possibility to connect supply hot water detection temperature sensor TM, for use with PS-CL/CLE/CLES/CLH/CLEH, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES, PS-DC/DCE/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory
Accessories for fan coils controls
KIT.TEL Wireless control panel signal receiver and PCB together with temperature probe, for installation inside fan coil unit with AC type fan, fits to PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
KIT.TEL
Wireless control panel signal receiver and PCB together with temperature probe, for installation inside fan coil unit with AC type fan, fits to PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
KIT.BUS Electronic board for PS-CL/CLE/CLES/CLH/CLEH, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DC/DCE/HDC/HDCE fan coil units connection to BMS via Mod-Bus protocol, delivered with air temperature probe
KIT.BUS
Electronic board for PS-CL/CLE/CLES/CLH/CLEH, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DC/DCE/HDC/HDCE fan coil units connection to BMS via Mod-Bus protocol, delivered with air temperature probe
DIS.BUS Information screen to display data from device controlled via KIT.BUS electronic board
DIS.BUS
Information screen to display data from device controlled via KIT.BUS electronic board
IDP Power interface distributor that allows to use single TER.ANA / TER.ANA.M / TER.ANA.S / TER.ANA.S.M / TER.DIG / TER.DIG.M / TER.DIG.D / TER.DIG.D.M / TER.DIG.S / TER.TOUCH / TER.TOUCH.M control panel for up to 4 fan coil units with AC type fans
IDP
Power interface distributor that allows to use single TER.ANA / TER.ANA.M / TER.ANA.S / TER.ANA.S.M / TER.DIG / TER.DIG.M / TER.DIG.D / TER.DIG.D.M / TER.DIG.S / TER.TOUCH / TER.TOUCH.M control panel for up to 4 fan coil units with AC type fans
SM Temperature sensor for automatic summer/winter mode change-over in TER.DIG.S / TER.EC.DIG control panels (to be used with units without valve or with 3-way valve), it also can be used as a remote air temperature sensor for TER.ANA(.M) / TER.ANA.S(.M) / TER.EC.ANA(.M) / TER.DIG(.M) / TER.DIG.S / TER.EC.DIG(.M) / TER.BUS(.M) / TER.BAC(.M) / TER.EC.BUS(.M) / TER.EC.BAC / TER.TOUCH(.M) / TER.EC.TOUCH(.M) control panels
SM
Temperature sensor for automatic summer/winter mode change-over in TER.DIG.S / TER.EC.DIG control panels (to be used with units without valve or with 3-way valve), it also can be used as a remote air temperature sensor for TER.ANA(.M) / TER.ANA.S(.M) / TER.EC.ANA(.M) / TER.DIG(.M) / TER.DIG.S / TER.EC.DIG(.M) / TER.BUS(.M) / TER.BAC(.M) / TER.EC.BUS(.M) / TER.EC.BAC / TER.TOUCH(.M) / TER.EC.TOUCH(.M) control panels
TM Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.ANA.S / TER.ANA.S.M / TER.DIG.S / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TEL control panels
TM
Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.ANA.S / TER.ANA.S.M / TER.DIG.S / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TEL control panels
Water valves
ATT.230 On/Off actuator for water valve, powered by 230 V
ATT.230
On/Off actuator for water valve, powered by 230 V
ATT.230.M On/Off actuator for water valve, powered by 230 V, with limit switch
ATT.230.M
On/Off actuator for water valve, powered by 230 V, with limit switch
ATT.MOD Modulating by 0-10 V signal actuator for water valve
ATT.MOD
Modulating by 0-10 V signal actuator for water valve
VAL.2V.34.CL 2-way water valve for PS-CL/CLE/CLES/CLH/CLEH fan coil units, 3/4" connection
VAL.2V.34.CL
2-way water valve for PS-CL/CLE/CLES/CLH/CLEH fan coil units, 3/4" connection
VAL.3V.34.CL 3-way water valve for PS-CL/CLE/CLES/CLH/CLEH fan coil units, 3/4" connection
VAL.3V.34.CL
3-way water valve for PS-CL/CLE/CLES/CLH/CLEH fan coil units, 3/4" connection
VAL.34.DIN.CL Balancing water valve for PS-CL/CLE/CLES/CLH/CLEH fan coil units, 3/4" connection
VAL.34.DIN.CL
Balancing water valve for PS-CL/CLE/CLES/CLH/CLEH fan coil units, 3/4" connection
Condensate collection trays
BAC.VAL1 Auxiliary drain pan for valve of 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units
BAC.VAL1
Auxiliary drain pan for valve of 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units
Diffusers
PAN.MET.050 Metal diffuser with Coanda effect for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units, RAL9003 spalva
PAN.MET.050
Metal diffuser with Coanda effect for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units, RAL9003 spalva
Air filters
FILTRO G4 G4 class air filter for PS-CL/CLE/CLES/CLH/CLEH fan coil units with PAN.MET.050 / PAN.MET.100 metal diffuser
FILTRO G4
G4 class air filter for PS-CL/CLE/CLES/CLH/CLEH fan coil units with PAN.MET.050 / PAN.MET.100 metal diffuser
Additional accessories for fan coils air inlet and outlet
FL.RIN Fresh air inlet flange for PS-CL/CLE/CLES/CLH/CLEH fan coil units
FL.RIN
Fresh air inlet flange for PS-CL/CLE/CLES/CLH/CLEH fan coil units
FL.AIR Flange for air supply to the adjacent room, fits PS-CL/CLE/CLES/CLH/CLEH fan coil units
FL.AIR
Flange for air supply to the adjacent room, fits PS-CL/CLE/CLES/CLH/CLEH fan coil units
Outer casings
KIT.COV.050 Metal outer casing for 050 - 094 size PS-CL/CLE/CLES fan coil units, painted in RAL9003 color
KIT.COV.050
Metal outer casing for 050 - 094 size PS-CL/CLE/CLES fan coil units, painted in RAL9003 color
Electric heating elements
KIT.RES.050 1.5 kW power electric heating element for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units
KIT.RES.050
1.5 kW power electric heating element for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units
Painting in non-standard colors
PAN.RAL.050 Painting of ABS plastic diffuser in non-standard RAL color for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units
PAN.RAL.050
Painting of ABS plastic diffuser in non-standard RAL color for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units
PAN.MET.RAL.050 Painting of metal diffuser in non-standard RAL color for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units
PAN.MET.RAL.050
Painting of metal diffuser in non-standard RAL color for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units